Challenge
A veterinary pharmaceutical firm in the Midwest upgraded a USP Purified Water system that was not consistently producing water of adequate quality – both conductivity and microbial. The customer did not want to use chemicals to regenerate ion exchange beds and is located far from any service deionization facilities.
Solution
Siemens installed a new hot water sanitizable continuous deionization (CDI®) system downstream of an existing two pass reverse osmosis unit.
- The product water conductivity improved dramatically.
- The CDI unit is hot (80 ºC) water sanitizable, improving microbial control.
Results
- Conductivity averages 0.07 microsiemen/cm
- TOC averages 11 ppb
- Microbial counts average 1 CFU/100 ml
- Down time for sanitization has been dramatically reduced.
- The system requires less operator attention than before the upgrade.
- Validation of the changes was quick and easy.
- The customer was so satisfied that they copied the upgrade design for other systems.