SIEMENS

 

Water Purification Systems 


Water Technologies

    X

    Contact


    search

    • Water Technologies
      • Products
      • Services
      • Parts
      • Municipal
      • Industries
      • Laboratory
      • Aquatics and Leisure
      • Applications
      • About Us
      • Site Map
    • Products
      • Activated Carbon
      • Aeration
      • Biological Treatment
      • Chemical Feed and Disinfection
      • Controls, Instrumentation and Analyzers
      • Conventional Filtration
      • Ion Exchange
      • Laboratory Water Products
      • Liquid and Vapor Phase Odor Control
      • Membrane Filtration & Separation
      • Physical/ Chemical Treatment
      • Separation and Clarification
      • Sludge and Biosolids Processing
      • Specialty Products and Accessories
    • Laboratory Water Products
      • Storage Reservoirs and other Accessories
      • Water Purification Systems
    • Water Purification Systems

    MEDICA® Range of Laboratory Water Purification Systems for Clinical Analyzers

    Pure water is vital for trouble free analysis. The MEDICA® range of lab water systems deliver CLRW grade water (clinical laboratory reagent water) to clinical chemistry and immunodiagnostic analyzers. 

    MEDICA® water systems come in a choice of models and flow rates to meet your unique requirements.  Choose MEDICA S/R/D (7/15), MEDICA Pro S/R/RE (30/60/120) or the MEDICA R-200, for higher flow rates.


    Is Your Water Ruining Your Test Results?  Look below for some hints and tips for your water system - and ask for your own Free Clinical Water Guide!

    MEDICA Pro with storage reservoir

    View our short Capabilities video

    Ask for your own FREE Clinical Water Guide  Learn about water systems and technologies needed to produce suitable quality water for clinical analyzers 

    Tips and Hints
    Did you know that storing purified water that is not recirculated should be kept to an absolute minimum to restrict deterioration in quality and bacterial growth?

    Did you know the electrodes of the line cell in the resistivity meter should be cleaned every 12 months by a qualified individual?

    Did you know regular sanitization of your water system is essential to prevent build-up of biofilm?

    The importance of water purity
    Laboratory monitoring of TOC in ultra-pure water (pdf)
    Preventing microbial growth in analytical grade water (pdf)

    top of page

    Features and Benefits

    MEDICA® S/R/D 7/15 - compact system utilizing pretreatment, reverse osmosis, deionization, UV photo oxidation and microfiltration to produce CLRW grade water to feed low volume clinical analyzers (Model D has degassing feature).

    • 1 to 15 megohm purity water
    • Flow rates from 7 lph to 200 lph
    • Easy front-loading cartridges
    • Microprocessor controlled system management with continuous water quality monitoring through an LCD display
    • Recirculating models available to ensure consistent purity
    • System comes complete with all cartridges

    MEDICA® Pro S/R/RE 30/60/120 - complete with a 50 liter, built-in water storage reservoir and long lasting deionization cartridges, this system is available in 30, 60 or 120 liters per hour flow rates and is available in a space saving design which can be upgraded for higher flow rates.

    • Quick and easy data download with mass storage device
    • User recognition key for improved security
    • E- Cartridge for reduced CO2
    • Castors available for easy system movement 

    MEDICA-R 200 - designed to supply up to 16 liters per minute of CLRW water to higher volume or multiple clinical analyzers in a loop. Its easy to install and operate, and can be customized to your requirements.

    • Delivers up to 16 liters per minute of CLRW Type 1 water
    • one compact unit -can be positioned inside the lab
    • easily connected to new or existing building management systems and can be easily sanitized
    • Audio visual alarms

    Tips and Hints
    Did you know that storing purified water that is not recirculated should be kept to an absolute minimum to restrict deterioration in quality and bacterial growth?

    Did you know the electrodes of the line cell in the resistivity meter should be cleaned every 12 months by a qualified individual?

    Did you know regular sanitization of your water system is essential to prevent build-up of biofilm?

    The importance of water purity
    Laboratory monitoring of TOC in ultra-pure water (pdf)
    Preventing microbial growth in analytical grade water (pdf)

    top of page
    Print
    Contact Us

    Contact Us

    Nick Armstrong
    Associate Product Manager
    800.875.7873 Ext. 5000
    Send Email
    Request a Proposal

    Product Documentation

    MEDICA systems brochure


    Specifications
    MEDICA range (pdf) 
    MEDICA Pro (pdf)
    MEDICA R-200 (pdf)

     

    Tips and hints are reprinted with permission from ELGA LabWater.  

    MEDICA is a trademark of ELGA LabWater

    Parts & Services

    Additional Products
    Storage reservoirs for 7/15 models (pdf)
    DV-25 liter docking vessel needed for 7/15 models (pdf)
    Replacement Cartridges (pdf) 

    Services
    Leasing Programs
    Service Deionization (SDI)

    Important product information

    Emergency by-pass loop, ensures uninterrupted water to the analyzer.

    MEDICA-R 200 includes internal 350 liter reservoir and can supply up to 16 lpm of CLRW grade water

    Featured Case Studies

     Delivering High Purity Water to a new research lab
     Helping a University research Lab produce high purity water for HIV research